On/off Air-Water heat pump Eco Hot Water, for domestic hot water with integrated solar panels and remote control via App

Composition
 
Constructional characteristics
EQ 2018 MODEL
• Capacity 200 liters
• S235 JR steel boiler with internal inorganic coating.

EQ 3018 ES MODEL
• Capacity 300 liters
• AISI 316-L stainless steel boiler with internal pickling coating.
• Exchanger for solar integration with a surface of 1 m², water content 3,8 lts.

BOTH MODELS
• Insulation in rigid polyurethane foam (PU) of high thickness and without CFC and HCFC, average thickness 50 mm.
• Anticorrosion electronic anode (2 in the 300 lts model).
• External painted sheet metal with epoxy powders (silver gray color).
• Stainless steel heat exchanger for solar or boiler integration
• Touch screen control panel, backlit to allow the different working parameters settings within 24 hours.
• Hydraulic fittings placed on the left side.
• 1.5 kW 230 V~ electric heater integration. Manually activable through control panel or automatically as heating pump integration or anti-legionella treatment.
• R134a ecological refrigerant fluid.
• Rotary compressor for the maximum quiet operation.
• Centrifugal fan.
• Condenser wrapped around the steel boiler (not immersed in the water).

Working range
Inlet air temperature: -5 - 43 °C
Water temperature (heat pump): 9 - 60 °C
Installation room temperature: 5 - 35 °C
Minimum volume of room installation: 30 m³

Loading...

Notes
 
Energy efficiency class (⁴): A+ (A+)
Refrigerant R134a (GWP=1430) - Power supply: 230V~ 50Hz - Weight (net/with water): 115/315 kg (EQ 2018), 122/422 kg ( EQ 3018 ES)

(¹) Heating up of the tank from 10 °C to the thermostat temperature
(²) COP calculated following the water draw-offs of the load profile
(³) Data according the standard EN 16147:2017. Heat source: Indoor air DB 20 °C ( Outdoor air DB 7 °C )
(⁴) Data according the regulation UE N. 812-814/2013. Heat source: Indoor air DB 20 °C ( Outdoor air DB 7 °C )

* Installation not ducted wit intake and exaust air from indoor
** Installation ducted wit intake and exaust air from outdoor
 