Registration

 
 
Province
 
State
 
 
 
Profession
 
 
 
 
 
Login
 
Recover password
 

DC-Inverter Air-Water monobloc heat pump Mirai SMI for Heating andCooling Residential environments with plant management system integrated

Composition
 
Construction
  • 1 PCB-Main Electronic board
  • 2 SMART-MT controller
  • 3 PCB-Main display
  • 4 PCB-Terminal Block System
  • 5 Air vent valve
  • 6 Safety valve
  • 7 Supply terminal block
  • 8 Heat exchanger (water)
  • 9 DC-Inverter compressor
  • 10 Water discharge valve
  • 11 Circulation pump
  • 12 Sensor of external air temperature
  • 13 Heat exchanger (air)
  • 14 Water flow connection to the system
  • 15 Serial number
  • 16 Base heater
  • 17 Water return connection from the system

Constructional characteristics
• DC-Inverter hermetically sealed compressor and thermal protection.
• Electronic expansion valve.
• Water side plate exchanger.
• Air side exchanger with aluminium flaps and copper pipes.
• Propeller type fan with brushless DC motor and accident-prevention protective grid.
• Innovative SMART-MT regulator.
• PCB-Terminal Block electronic board.
• Painted steel structure.

Working range
Maximum outdoor temperature: 43 °C (Cooling), 43 °C (Heating)
Maximum water temperature: 23 °C (Cooling), 60 °C (Heating)
Minimum outdoor temperature: 18 °C (Cooling), -20 °C (Heating)
Minimum water temperature: 6 °C (Cooling), 23 °C (Heating)

Loading...

Notes
 
PARAMETERS DECLARED FOR MEDIUM (LOW) TEMPERATURE APPLICATION (²)

Seasonal space heating energy efficiency class:
EH0615 - 1015DC models: A+ (A++) / EH1315-1615DC and EH1718D3 models: A++ (A++)

Sound power (³): EH0615DC model: 60 dB(A) / EH1015-1615DC and EH1718D3 models: 62 dB(A)

......................................................................................................................................................

Refrigerant: EH0615-1615DC models: R410A / EH1718D3 model: R32
Power supply: EH0615-1615DC models: 230V~ 50Hz / EH1718D3 model: 400V 3N~ / 50Hz
Data referred to the application with radiant panels (¹) and to the following conditions:
(*) Air: 7(6) °C - Water: 30/35 °C (Ref. A7 W35)
(**) Air: 35 °C - Water: 18/23 °C (Ref. A35 W18)

(¹) Data referred to the standard EN 14511:2013
(²) Data referred to the Regulation EU N. 811-813/2013 and standards EN 14825:2016, EN 14511:2013