Single Inverter duct air conditioner EIDH 12÷36 kBtu

Ducted models characteristics:
-Compact design: Ducted models 12-18-24K have reduced dimensions (185 mm height) to minimize the overall dimensions.
-Condensate drain pan: Unit contains a condensate drain pan easy to be removed, besides a drainage on the two sides can be realized just by changing the drain pan direction.
-Installation simple and flexible:Thanks to its very compact dimensions, installation results simple and flexible. Ducting can be rounded or rectangular. 28-36K model has the advantage to set the number of the air flow and its fixing position according to the rooms schema, once the load and the constant temperature of the single room have been considered sufficient it allows to realize a system in perfect comfort.
Operation and technical characteristics:
-Cooling mode
-Heating mode
-DRY/Dehumidification: To reduce relative humidity without turning the temperature down too much.
-AUTO/Automatic mode: It chooses functioning mode according to the set parameters to allow an ideal and comfortable condition to the ambience.
-Ventilation mode: Three speeds available plus automatic.
-Wire remote control: Standard connection with cable length mt 19.
-TIMER/Timer setting: To preset the startup and the shutdown of the air conditioner.
-SLEEP/Night-time setting: To maintain optimum temperature during sleep periods.
-AUTODIAGNOSIS/Maintenance: It indicates any functioning problems.
-AUTORESTART/Automatic restarting: To automatically restart the system after an interruption of the power supply.
-Anti-dust filter: The indoor unit is equipped with a purification filter of the dust.
-Key Lock of the wire remote control: To block all the functions directly from the wire remote control.
-Double temperature range: It allows to set/visualize the temperature in °C or °F.
-Soft mode: To achieve conditions of lower noisiness.
-Compressor maintenance: To ensure a longer compressor lifetime, we have equipped the compressor with a start and stop controller. Waiting time between stop and start is three minutes.
-Power mode: To obtain quick Cooling or Heating.
-On-off card: Card to activate the functioning of the indoor unit.


The indoor units (IU) above must be combined with the following outdoor units (OU):
EIDH-1214S (IU) : EOSH-1214 (OU)
EIDH-1814S (IU) : EOSH-1814 (OU)
EIDH-2414S (IU) : EOSH-2414 (OU)
EIDH-2813M (IU) : EOSH-2814 (OU)
EIDH-3613M (IU) : EOSH-3614 (OU)

Refrigerant R410A (GWP = 2088) - Power supply (V-ph-Hz): 230-1-50
Performance data refer to the combination of the indoor unit (IU) with its outdoor unit (OU)
(*) Cooling standard design/nominal conditions: internal temperature = 27(19) °C; external temperature = 35 °C
(**) Heating standard nominal conditions: internal temperature = 20 °C; external temperature = 7 °C