Single Inverter floor/ceiling air conditioner EIFH 48÷60 kBtu

Floor/ceiling models characteristics:
-Condensate drain pan: Unit contains a condensate drain pan which allows to collect the water installing the unit both horizontally and vertically.
-Installation simple and flexible: Thanks to its very compact dimensions, installation results simple and flexible given that the internal unit can be placed on the floor or on the ceiling according to the needs.
-Easy and quick maintenance: From the frontal panel you can easily access to the filters to clean them periodically or to substitute them.
-Automatic check of the air distribution: To obtain areas with a constant temperature, the air conditioner uses two louvers to regulate the air flow automatically and to address the air to every corner of the room. In Heating mode it will distribute a big quantity of warm air to heat quickly and efficiently above the floor. In Cooling mode it will direct the air flow from upwards to downwards until cool air will reach every corner of the room. Air flow direction can be controlled in 5 position: from upwards to downwards and from the left to the right.
Operation and technical characteristics:
-Cooling mode
-Heating mode
-DRY/Dehumidification: To reduce relative humidity without turning the temperature down too much.
-AUTO/Automatic mode: It chooses functioning mode according to the set parameters to allow an ideal and comfortable condition to the ambience.
-Ventilation mode: Three speeds available plus automatic.
-Remote control: Liquid crystal display (LCD) with clear indication of functions.
-TIMER/Timer setting: To preset the startup and the shutdown of the air conditioner.
-SLEEP/Night-time setting: To maintain optimum temperature during sleep periods.
-AIRSWING/Manual movement of vertical deflector: To manually adjust air flux vertical.
-AUTODIAGNOSIS/Maintenance: It indicates any functioning problems.
-AUTORESTART/Automatic restarting: To automatically restart the system after an interruption of the power supply.
-Anti-dust filter: The indoor unit is equipped with a purification filter of the dust.
-Key Lock of the remote control: To block all the remote control functions
-Double temperature range: It allows to set/visualize the temperature in °C or °F.
-Soft mode: To achieve conditions of lower noisiness.
-Compressor maintenance: To ensure a longer compressor lifetime, we have equipped the compressor with a start and stop controller. Waiting time between stop and start is three minutes.
-Manual movement of horizontal deflector: To manually adjust air flux horizontally.
-Power mode: To obtain quick Cooling or Heating.
-On-off card: Card to activate the functioning of the indoor unit.


The indoor units (IU) above must be combined with the following outdoor units (OU):
EIFH-4813 (IU) : EOSH-4813 (OU)
EIFH-6013 (IU) : EOSH-6013 (OU)

Refrigerant R410A (GWP = 2088) - Power supply (V-ph-Hz): 230-1-50 (IU), 400-3-50 (OU)
Performance data refer to the combination of the indoor unit (IU) with its outdoor unit (OU)
(*) Cooling standard design/nominal conditions: internal temperature = 27(19) °C; external temperature = 35 °C
(**) Heating standard nominal conditions: internal temperature = 20 °C; external temperature = 7 °C